BECKHOFF KL3062 Specification

  • IP Rating
  • IP20
  • Shape
  • Rectangular
  • Overheating Protection
  • Yes, electronic protection
  • Mounting Type
  • DIN Rail
  • Operating Temperature
  • 0C to +55C
  • Surface Finish
  • Matte
  • Humidity %
  • 95% maximum, non-condensing
  • Efficiency
  • High precision measurement
  • Connector Type
  • Terminal clamp
  • Feature
  • Hot connect/disconnect, Bus Coupler support
  • Insulation Material
  • High-grade Plastic
  • Product Type
  • Analog Input Terminal
  • Application
  • Current Measurement, Industrial Automation
  • Protection Level
  • Basic Insulation
  • Frequency (MHz)
  • 50/60 Hz
  • Rated Voltage
  • 24 V DC (Power supply via K-bus)
  • Energy Consumption
  • Typically 0.90 W
  • Output Type
  • Analog
  • Color
  • Light Grey
  • Dimension (L*W*H)
  • 68 x 12 x 100 mm
  • Weight
  • Approx. 60 g
  • Size
  • Standard I/O terminal size
  • Input Voltage
  • 24 V DC
  • Phase
  • Single
  • Material
  • Plastic, Metal
  • No Of Poles
  • 2
  • Connection Type
  • 2-wire
  • Number of Channels
  • 2 Analog Input channels
  • Response Time
  • < 10 ms
  • Input Current Range
  • 0-20 mA
  • Operating Mode
  • Current measurement, different potentials between channels possible
  • Signal Connection Type
  • Single-ended
  • Type Code
  • KL3062
  • Isolation
  • 3.5 kV (E-bus/signal voltage)
  • Resolution
  • 12 bit
  • System Bus
  • K-bus
 
 

About BECKHOFF KL3062



Discover the BECKHOFF KL3062, a trending and exclusive analog input terminal designed for elite industrial automation setups. With 2 unassailable analog input channels (0-20mA) and excellent 12-bit resolution, this device delivers high-precision current measurement in a compact, standard I/O terminal size. Its robust 3.5 kV isolation, basic insulation, and electronic overheating protection ensure safety and reliability. Featuring hot connect/disconnect capability and compatibility with the K-bus system, the KL3062 offers excellent efficiency, supporting both dealers and distributors with exceptional German engineering at a discounted, competitive rate.

Versatile Industrial Application

The BECKHOFF KL3062 is crafted for usage in demanding industrial environments. Primarily used for current measurement, it's tailored to integrate seamlessly with systems requiring analog signal detection and monitoring. This module excels in industrial automation solutions, with the flexibility to handle different potentials between channels. Its reliability suits applications in manufacturing plants, process control, and precision monitoring-making it indispensable for electrical engineers and system integrators aiming for operational excellence.


Secure Packaging and Export Value

BECKHOFF KL3062 units are shipped in market-value secure packaging, ensuring efficient protection during transit. Designed for global markets, this module is favored in regions with thriving industrial automation sectors. Export charges are based on destination and volume, with sample units available to qualified buyers upon request. As a sought-after German-manufactured product, it retains value across major export areas, serving wholesalers, dealers, and service providers who demand only the best in automation technology.


FAQ's of BECKHOFF KL3062:


Q: How does the BECKHOFF KL3062 protect against overheating during prolonged use?

A: The KL3062 is engineered with electronic overheating protection, which continuously monitors the device's temperature and prevents damage by activating protection circuits when thresholds are exceeded.

Q: What benefits does the 3.5 kV isolation provide in industrial applications?

A: The 3.5 kV isolation ensures safe separation between the E-bus and signal voltage, protecting both the device and connected systems from electrical surges and potential cross-channel interference, thus enhancing longevity and safety.

Q: What is the process for connecting the KL3062 to a DIN rail system?

A: Simply mount the module onto a standard DIN rail and secure the terminal clamp connections. The K-bus interface allows for quick integration with other compatible devices, streamlining the installation process.

Q: Where is the BECKHOFF KL3062 primarily used?

A: This analog input terminal is widely used in industrial automation environments, such as factories, power plants, and process control systems, where precise current measurement is necessary for system monitoring and control.

Q: When should you opt for a single-ended signal connection type like the KL3062 offers?

A: Choose single-ended connections for applications where the reference point is common for all signals, simplifying the wiring and reducing potential cost, especially when differential noise is minimal in your environment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in BECKHOFF PLC AND HMI Category

BECKHOFF KL6021

BECKHOFF KL6021

Price 3000 INR / Piece

Minimum Order Quantity : 1 Piece

Feature : Compact serial interface for RS232 communication

Phase : Single

Operating Temperature : 0 C to +55 C

Surface Finish : Matte

BECKHOFF BK5250

BECKHOFF BK5250

Minimum Order Quantity : 1 Piece

Feature : Supports up to 64 Bus Terminals (255 with Kbus extension); integrated addressing switch

Phase : Single Phase

Operating Temperature : 0C to +55C

Surface Finish : Matt

BECKHOFF KL2794

BECKHOFF KL2794

Price 3000 INR / Piece

Minimum Order Quantity : 1 Piece

Feature : Manual Override, Status LEDs

Phase : Single Phase

Operating Temperature : 0C to +55C

Surface Finish : Matte

BACKHOFF EK1122

BACKHOFF EK1122

Price 3000 INR / Piece

Minimum Order Quantity : 1 Piece

Feature : DIN rail mountable, plugin connection

Phase : Single Phase

Operating Temperature : 0...55 C

Surface Finish : Matte



Back to top